Siemens
Contactor de potencia Siemens 3RT2038-1AK60
SKU: SIEMEN-3RT2038-1AK60
Contactor de potencia Siemens modelo 3RT2038-1AK60.
$5,399.65
Últimas 5 piezas
Descripción técnica
**Contactor de potencia Siemens 3RT2038-1AK60**
Contactor de potencia Siemens modelo 3RT2038-1AK60.
### Descripción del fabricante
power contactor, AC-3e/AC-3, 80 A, 37 kW / 400 V, 3-pole, 110 V AC, 50 Hz / 120 V, 60 Hz, auxiliary contacts: 1 NO + 1 NC, screw terminal, size: S2
**Entrega estimada:** 1 a 3 días hábiles (en existencia).
Fuente: [Siemens (sitio oficial)](https://sieportal.siemens.com/en-ww/products-services/detail/3RT2038-1AK60)
Categoría: Potencia y control de motores
Especificaciones
| General | |
|---|---|
| product brand name | SIRIUS |
| product designation | Power contactor |
| product type designation | 3RT2 |
| size of contactor | S2 |
| function module for communication | No |
| auxiliary switch | Yes |
| at AC in hot operating state | 17.1 W |
| at AC in hot operating state per pole | 5.7 W |
| without load current share typical | 6.5 W |
| type of calculation of power loss current-dependent | quadratic |
| of main circuit with degree of pollution 3 rated value | 690 V |
| of auxiliary circuit with degree of pollution 3 rated value | 690 V |
| of main circuit rated value | 6 kV |
| of auxiliary circuit rated value | 6 kV |
| maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1 | 400 V |
| at AC | 11.8 g / 5 ms, 7.4 g / 10 ms |
| of contactor typical | 10 000 000 |
| of the contactor with added electronically optimized auxiliary switch block typical | 5 000 000 |
| of the contactor with added auxiliary switch block typical | 10 000 000 |
| reference code according to IEC 81346-2 | Q |
| Substance Prohibitance (day/month/year) | 10/01/2014 |
| Net Weight | 0.958 kg |
| installation altitude at height above sea level maximum | 2 000 m |
| during operation | -25 ... +60 °C |
| during storage | -55 ... +80 °C |
| relative humidity minimum | 10 % |
| relative humidity at 55 °C according to IEC 60068-2-30 maximum | 95 % |
| number of poles for main current circuit | 3 |
| number of NO contacts for main contacts | 3 |
| number of NC contacts for main contacts | 0 |
| at AC-3 rated value maximum | 690 V |
| at AC-3e rated value maximum | 690 V |
| at AC-1 at 400 V at ambient temperature 40 °C rated value | 90 A |
| up to 690 V at ambient temperature 40 °C rated value | 90 A |
| up to 690 V at ambient temperature 60 °C rated value | 80 A |
| at 400 V rated value | 80 A |
| at 500 V rated value | 80 A |
| at 690 V rated value | 58 A |
| at AC-4 at 400 V rated value | 55 A |
| at AC-5a up to 690 V rated value | 79.2 A |