Siemens
Relevador de sobrecarga térmica Siemens 3RU2136-4FB0
SKU: SIEMEN-3RU2136-4FB0
Relevador de sobrecarga térmica Siemens modelo 3RU2136-4FB0.
$1,859.87
Últimas 4 piezas
Descripción técnica
**Relevador de sobrecarga térmica Siemens 3RU2136-4FB0**
Relevador de sobrecarga térmica Siemens modelo 3RU2136-4FB0.
### Descripción del fabricante
Overload relay 28...40 A Thermal For motor protection Size S2, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset
**Entrega estimada:** 1 a 3 días hábiles (en existencia).
Fuente: [Siemens (sitio oficial)](https://sieportal.siemens.com/en-ww/products-services/detail/3RU2136-4FB0)
Categoría: Potencia y control de motores
Especificaciones
| General | |
|---|---|
| product brand name | SIRIUS |
| product designation | thermal overload relay |
| product type designation | 3RU2 |
| size of overload relay | S2 |
| size of contactor can be combined company-specific | S2 |
| power loss [W] for rated value of the current at AC in hot operating state | 15.6 W |
| per pole | 5.2 W |
| type of calculation of power loss current-dependent | quadratic |
| insulation voltage with degree of pollution 3 at AC rated value | 690 V |
| surge voltage resistance rated value | 6 kV |
| in networks with ungrounded star point between auxiliary and auxiliary circuit | 415 V |
| in networks with grounded star point between auxiliary and auxiliary circuit | 415 V |
| in networks with ungrounded star point between main and auxiliary circuit | 690 V |
| in networks with grounded star point between main and auxiliary circuit | 690 V |
| shock resistance according to IEC 60068-2-27 | 8g / 11 ms |
| with automatic reset typical | 10 min |
| with remote-reset | 10 min |
| with manual reset | 10 min |
| reference code according to IEC 81346-2 | F |
| Substance Prohibitance (day/month/year) | 10/15/2014 |
| Net Weight | 304.8 g |
| installation altitude at height above sea level maximum | 2 000 m |
| during operation | -40 ... +70 °C |
| during storage | -55 ... +80 °C |
| during transport | -55 ... +80 °C |
| temperature compensation | -40 ... +60 °C |
| relative humidity during operation | 10 ... 95 % |
| number of poles for main current circuit | 3 |
| adjustable current response value current of the current-dependent overload release | 28 ... 40 A |
| rated value | 690 V |
| at AC-3e rated value maximum | 690 V |
| operating frequency rated value | 50 ... 60 Hz |
| operational current rated value | 40 A |
| operational current at AC-3e at 400 V rated value | 40 A |
| at 400 V rated value | 18.5 kW |
| at 500 V rated value | 22 kW |
| at 690 V rated value | 37 kW |
| design of the auxiliary switch | integrated |
| number of NC contacts for auxiliary contacts | 1 |
| note | for contactor disconnection |