Siemens
Guardamotor Siemens 3RV2011-1GA10
SKU: SIEMEN-3RV2011-1GA10
Guardamotor Siemens modelo 3RV2011-1GA10.
$1,740.14
Sin stock
Descripción técnica
**Guardamotor Siemens 3RV2011-1GA10**
Guardamotor Siemens modelo 3RV2011-1GA10.
### Descripción del fabricante
Circuit breaker size S00 for motor protection, CLASS 10 A-release 4.5...6.3 A N-release 82 A screw terminal Standard switching capacity
**Entrega estimada:** 10 a 15 días hábiles (bajo pedido).
Fuente: [Siemens (sitio oficial)](https://sieportal.siemens.com/en-ww/products-services/detail/3RV2011-1GA10)
Categoría: Potencia y control de motores
Especificaciones
| General | |
|---|---|
| product brand name | SIRIUS |
| product designation | Circuit breaker |
| design of the product | For motor protection |
| product type designation | 3RV2 |
| product feature of circuit breaker for motor protection complete unit with protection device | Yes |
| size of the circuit-breaker | S00 |
| size of contactor can be combined company-specific | S00, S0 |
| product function disconnector functionality | Yes |
| product extension auxiliary switch | Yes |
| at AC in hot operating state | 7.25 W |
| at AC in hot operating state per pole | 2.4 W |
| type of calculation of power loss current-dependent | quadratic |
| insulation voltage with degree of pollution 3 at AC rated value | 690 V |
| surge voltage resistance rated value | 6 kV |
| in networks with ungrounded star point between main and auxiliary circuit | 400 V |
| in networks with grounded star point between main and auxiliary circuit | 400 V |
| on the front according to IEC 60529 | IP20 |
| on the front | IP20 |
| of the terminal | IP20 |
| shock resistance according to IEC 60068-2-27 | 25g / 11 ms |
| of the main contacts typical | 100 000 |
| of auxiliary contacts typical | 100 000 |
| electrical endurance (operating cycles) typical | 100 000 |
| reference code according to IEC 81346-2 | Q |
| continuous current rated value | 6.3 A |
| Substance Prohibitance (day/month/year) | 10/01/2009 |
| Net Weight | 328.6 g |
| installation altitude at height above sea level maximum | 2 000 m |
| during operation | -20 ... +60 °C |
| during storage | -50 ... +80 °C |
| during transport | -50 ... +80 °C |
| temperature compensation | -20 ... +60 °C |
| relative humidity during operation | 10 ... 95 % |
| number of poles for main current circuit | 3 |
| adjustable current response value current of the current-dependent overload release | 4.5 ... 6.3 A |
| type of voltage for main current circuit | AC |
| rated value | 690 V |
| at AC-3 rated value maximum | 690 V |
| at AC-3e rated value maximum | 690 V |
| operating frequency rated value | 50 ... 60 Hz |