Eaton · Moeller
Bloque de disparo 3–12 A Eaton PKE-XTU-12
SKU: EATON-PKE-XTU-12
Bloque de disparo 3–12 A Eaton modelo PKE-XTU-12.
$3,660.44MXN + IVA
En existencia
- Entrega estimada: 1–3 días hábiles
- Envío asegurado en pedidos de alto valor
- Peso: 0.47 kg
- Medidas: 16 × 14 × 8 cm
Descripción técnica
Bloque de disparo 3–12 A Eaton PKE-XTU-12
Bloque de disparo 3–12 A Eaton modelo PKE-XTU-12.
Descripción del fabricante
158243 - Eaton Moeller® series PKE12 Motor-protective circuit-breaker, Complete device with AK lockable rotary handle, Electronic, 3 - 12 A, With overload release
Entrega estimada: 1 a 3 días hábiles (en existencia).
Fuente: Eaton (sitio oficial)
Categoría: Potencia y control de motores
Especificaciones
| General | |
|---|---|
| Model Code | PKE12/AK/XTU-12 |
| Largo | 101 mm |
| Alto | 120 mm |
| Ancho | 45 mm |
| Peso | 0.425 kg |
| Certificaciones | IEC/EN 60947 UL File No.: E36332 CE CSA UL 60947-4-1 IEC/EN 60947-4-1 VDE 0660 CSA Class No.: 3211-05 UL CSA File No.: 165628 CSA-C22.2 No. 60947-4-1-14 UL Category Control No.: NLRV |
| Catalog Notes | This is a product for Environment A (Industrial). In environment B (household) this device may cause undesirable radio interference. In this case the user may be obliged to take appropriate measures. |
| Global Catalog | 158243 |
| Tipo de producto | System-protective circuit-breaker |
| Features | Phase-failure sensitivity (according to IEC/EN 60947-4-1, VDE 0660 Part 102) |
| 10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| 10.2.2 Corrosion resistance | Meets the product standard's requirements. |
| 10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. |
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. |
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | Meets the product standard's requirements. |
| 10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. |
| 10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.2.7 Inscriptions | Meets the product standard's requirements. |
| 10.3 Degree of protection of assemblies | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances | Meets the product standard's requirements. |
| 10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. |
| 10.8 Connections for external conductors | Is the panel builder's responsibility. |
| 10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. |
| 10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. |
| 10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. |
| Fitted with: | AK lockable rotary handle |
| Operating frequency | 60 Operations/h |
| Pollution degree | 3 |
| Lifespan, mechanical | 50,000 Operations (Main conducting paths) |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
| Actuator type | Turn button |
| Tripping characteristic | Class 5, 10, 15, 20 |
| Adjustment range short-term delayed short-circuit release - max | 186 A |
| Adjustment range short-term delayed short-circuit release - min | 47 A |
Productos relacionados

Protección térmica Siemens 3RB3123-4VB0
Entrega: 1–3 días hábiles
$6,361.15+ IVA
Últimas 5 piezas
Contactor Siemens 3RT2017-1BB41
Entrega: 1–3 días hábiles
$1,022.42+ IVA
En existencia
Bloque de contacto NA Eaton M22-K10
Entrega: 1–3 días hábiles
$79.91+ IVA
En existencia
Mecanismo de maneta para interruptor Eaton NZM1-XDVR
Entrega: 1–3 días hábiles
$949.52+ IVA
Últimas 5 piezas