¿Hablamos?
Relevador de sobrecarga térmica Siemens 3RU2136-4FB0
Siemens

Relevador de sobrecarga térmica Siemens 3RU2136-4FB0

SKU: SIEMEN-3RU2136-4FB0

Relevador de sobrecarga térmica Siemens modelo 3RU2136-4FB0.

$1,859.87MXN + IVA
Últimas 4 piezas
  • Entrega estimada: 1–3 días hábiles
  • Envío asegurado en pedidos de alto valor
  • Peso: 0.5 kg
  • Medidas: 15 × 12 × 10 cm
1
Cotizar por volumen

Descripción técnica

Relevador de sobrecarga térmica Siemens 3RU2136-4FB0

Relevador de sobrecarga térmica Siemens modelo 3RU2136-4FB0.

Descripción del fabricante

Overload relay 28...40 A Thermal For motor protection Size S2, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset

Entrega estimada: 1 a 3 días hábiles (en existencia).

Fuente: Siemens (sitio oficial)

Categoría: Potencia y control de motores

Especificaciones

Especificaciones técnicas
General
product brand nameSIRIUS
product designationthermal overload relay
product type designation3RU2
size of overload relayS2
size of contactor can be combined company-specificS2
power loss [W] for rated value of the current at AC in hot operating state15.6 W
per pole5.2 W
type of calculation of power loss current-dependentquadratic
insulation voltage with degree of pollution 3 at AC rated value690 V
surge voltage resistance rated value6 kV
in networks with ungrounded star point between auxiliary and auxiliary circuit415 V
in networks with grounded star point between auxiliary and auxiliary circuit415 V
in networks with ungrounded star point between main and auxiliary circuit690 V
in networks with grounded star point between main and auxiliary circuit690 V
shock resistance according to IEC 60068-2-278g / 11 ms
with automatic reset typical10 min
with remote-reset10 min
with manual reset10 min
reference code according to IEC 81346-2F
Substance Prohibitance (day/month/year)10/15/2014
Net Weight304.8 g
installation altitude at height above sea level maximum2 000 m
during operation-40 ... +70 °C
during storage-55 ... +80 °C
during transport-55 ... +80 °C
temperature compensation-40 ... +60 °C
relative humidity during operation10 ... 95 %
number of poles for main current circuit3
adjustable current response value current of the current-dependent overload release28 ... 40 A
rated value690 V
at AC-3e rated value maximum690 V
operating frequency rated value50 ... 60 Hz
operational current rated value40 A
operational current at AC-3e at 400 V rated value40 A
at 400 V rated value18.5 kW
at 500 V rated value22 kW
at 690 V rated value37 kW
design of the auxiliary switchintegrated
number of NC contacts for auxiliary contacts1
notefor contactor disconnection